Описание

Main Unit, General-purpose Type, 24 Optical Axes
Model SL-V24L
Detection capability o45 mm
Beam axis spacing/Lens diameter 40 mm/o5 mm
Effective aperture angle Max. ±2.5 ° (When operating distance is 3 m or more)
Working distance 0.1 m to 9.0 m (detection height of 1,260 mm or l ess) 0.1 m to 7.0 m (detection height of 1,400 mm or more)
Response time (ms) ON>OFF 9.2*1
OFF>ON 49.2*1
Light source Infrared LED (850 nm)
Operation mode Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)
OSSD output Output 2 outputs each for PNP and NPN. Can be changed by using the connector cable.
Max. l oad current 500 mA*2
Residual vol tage (during ON) Max. 2.5 V (with a cable length of 7 m)
Leakage current Max. 100 µA*3
Max. capacitive load 2.2 µF (with a load resistance of 100 ?)
Load wiring resistance Max. 2.5 ?*4
Non safety-rel atedoutput AUX Output with automatic PNP/NPN switching function, 50 mA max.
Interlock-reset-ready output
Alarm output
Clear/blocked output
State information output 1, 2
Muting lamp output Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected
Input EDM input Short-circuit current 10 mA
Wait input Short-circuit current 2.5 mA
Reset input
Muting input 1, 2
Override input
Protection circuit Reverse current protection, short-circuit protection for each output, surge protection for each output
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998
Rating Power voltage 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less
Current consumption (mA) When the Centre indicator is ON Transmitter 97*6
Receiver 82*6
When the Centre indicator is OFF Transmitter 88*6
Receiver 71*6
Environmental resistance Enclosure rating IP65 (IEC60529)
Overvoltage category II
Ambient light Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 15 to 85 % RH (No condensation)
Storage relative humidity 15 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Main unit case Aluminium
Upper case/lower case Zinc die-cast
Front cover Polycarbonate, SUS304
Weight Transmitter 650 g
Receiver 675 g
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit. e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), andSL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms. *2 When used under ambient temperature between 45 to 55 °C, the maximum should not exceed 300 mA. *3 Applies to situations when power is either off or disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 ? or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 ? or less. *5 When used under ambient temperature between 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA). *6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.) In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state. In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.
''